An XY chart with subformat "Lines Only" is saved as "Symbols and Lines" in Excel format. Saving in native format is correct. Added symbols are shown both by Excel and scalc. Possibly related to issue 6496.
Hi Bjoern, for you. tk
I'll take a look (ACCEPTED)
BM->DR: It looks like the filter would not set the chart type correctly. The XDiagram has a property "SymbolType" (see service XYDiagram/LineDiagram) which is "-3" meaning NONE. In this case the sub-chart type should change to "no symbols"
The property "SymbolType" of the diagram returns -3, as expected, but the same property from a single data row returns 0, and this is used to export the series. The return type should be -3 for all data rows and data points in charts without symbols.
Ok, I will check this.
data points and series now return -3 (NONE) for symbol type, if the chart type has no symbols.
->AF: please review my fixes.
Bug fix reviewed.
Fixed in CWS sch7pp2
Please verify (sch7pp2 is on cwsserver 3).
Export Selection in Excel is none. Import Selection in Calc is wrong.
review done
Fixed import and export of line charts and XY charts (CWS FIX645/sch7pp2). On Excel import: Correct setting of chart type according to visibility of lines and symbols (did not work for symbol-only XY charts too). Problem was that the chart type dialog did not show the correct chart type. On Excel export: Correct setting of chart type according to visibility of lines and symbols, and spline type. Problem was that Excel's chart type dialog did not show a selection in the chart type area. I will attach a test document containing all line/XY chart types. Note that a line chart without lines (symbols only) is a user-defined type, and therefore Excel correctly shows no selection in its dialog, in difference to a symbols-only XY chart.
fixed
Created attachment 11885 [details] test document with line/XY charts, for import/re-export
back to QA
verified in sch7pp2
verified
closed